Episode 101
101: Spring Updates for April 11, 2024
Talking points for this episode are:
- SRM diagnostics – break the system down as normal to isolate the issue. This does apply to diagnosing a 2150 as well.
- It never hurts to have a your configs backed up and in the cab. Whether you are updating to a .0 branch or once you update to a .1 branch and get it set up correctly, export your configurations and keep them in the cab.
- When setting up a liquid system with HD’s on it, rate controller. must be configured whether present or not.
2024.1.X Specific
- Sprayers need to be on .1.6 available on the cloud.
- If you are running on .1, stay up to date on the software updates. It helps us validate fixes we are putting into software but also will provide a better .1 experience.
- When setting up a liquid system, we have to select the correct style of Rate Control Module as well as the correct mode for the Rate Control Module (base/HD).
- When changing crop, be sure to change in the fields tab, products tab, active rows in equipment, as well as making sure we are changing our seeds/disk (the last page of vDrive setup).